How many screw piles does a 4×6 m deck need?

Back to the list of questions

How many screw piles does a 4×6 m deck need?

A 4 × 6 m deck needs 12 screw piles set out in a grid at 2 m spacing: 10 around the perimeter and 2 in a middle row. If the floor joists can span 4 m without an intermediate support, the middle row is dropped and 10 piles are enough. A barbecue, stove or stairs gets its own extra pile.

Where the number 12 comes from

Spacing is the distance between the centre lines of neighbouring piles. For a deck it is 2–2.5 m. For sides of 4 and 6 m we use 2 m, because both sides divide by it without a remainder.

  • Long side, 6 m: supports at 0, 2, 4 and 6 m, which is 4 piles.
  • Short side, 4 m: supports at 0, 2 and 4 m, which is 3 piles.
  • Perimeter: 2 × 4 + 2 × 3 − 4 = 10 piles. A corner pile belongs to two sides at once, so the 4 corners are subtracted to avoid counting them twice.
  • Middle row along the 6 m side: 2 more piles at the 2 m and 4 m marks.

The result is a 3 × 4 grid, or 12 supports.

When 10 piles are enough and when you need more

The middle row supports the joists halfway across the 4 m span. It is left out if the timber beam or steel section of the frame can carry that span without sagging. This depends on the joist cross-section, and we check it for each specific project.

You need more piles where the deck carries a point load: a built-in barbecue, a stove, roof posts or stairs. Each of these gets its own pile, regardless of the grid. We never design spacing over 3 m, even to save money, because at that distance the frame sags and the floor becomes springy over time.

If the deck will have a roof, the piles under its posts also take wind load that tries to pull them out of the ground. Then the second pile rating matters: uplift, or pull-out resistance. For SPGS F 60 × 3 × 1200 (500) it is 0.76 t, and for SPGS F 76 × 3 × 1500 (500) it is 1.27 t, so we recommend 76 mm piles under canopy posts.

What diameter and length the piles should be

For decks we use 60 mm piles. The SPGS F 60 × 3 × 1200 (500) model carries 1.38 t in compression. We build in a 25–30 % safety margin, so we put no more than 1.06 t on each pile, and 12 piles carry a deck with a total load of up to 12.7 t. That total includes the weight of the frame and decking, people, furniture, and snow, which is calculated for your area under Ukrainian building code DBN V.1.2-2:2006.

Pile length is calculated with the formula L1 = A + L2 + H, where:

  • A is the frost depth under Ukrainian building codes (about 0.9 m for Kyiv and the Kyiv region);
  • L2 is the length of the helix;
  • H is how far the pile stands above ground to carry the frame.

The helix must sit entirely below the frozen layer, otherwise frost heave will start pushing the pile up in winter. For a deck in the Kyiv region standing 300 mm above ground, that gives 900 + 650 + 300 = 1850 mm, so the SPGS F 60 × 3 × 2000 (650) pile is the right fit. The full step-by-step method is in our article “Calculating a ground screw pile foundation”.

What to send us for an exact calculation

The standard 3 × 4 grid suits a typical timber deck. To match the calculation to your project, send us the deck dimensions, its height above ground and the joist and decking materials, and tell us whether there will be a roof, a barbecue or stairs. Phone, Viber, Telegram and WhatsApp: +38 050 431-70-60. We install twelve piles in one day in any season, and the deck can be loaded straight after installation, with none of the weeks of waiting a concrete foundation needs. All our standard pile models are in the Ground screw piles section.


View screw piles in the catalogue

Back to the list of questions